Siemens SIM2K-140/141/341 / D160 - OBDII
This module is designed for reading, writing FLASH memory ECU the SiemensSIM2K-140/141/341 / D160 through the OBDII diagnostic connector. Working with the ECU data is carried out by CAN bus via J2534 compatible device as well as K-Line via USB K-Line Adapter .
ECU data set for Kia vehicles, Hyundai engine capacity of 2 liters or more, Chevrolet Epica (Siemens SIM2K-D160).
ECU data set for Kia vehicles, Hyundai engine capacity of 2 liters or more, Chevrolet Epica (Siemens SIM2K-D160).
As shown, writing FLASH ECU memory
Siemens SIM2K-140 is carried out by K-Line and recording ECU
Siemens SIM2K-141/341 is carried out on the CAN bus .
Siemens SIM2K-140 is carried out on the CAN bus.
If you try to write the firmware in the FLASH memory of the ECU, which is written by K-Line firmware on the CAN bus, it can lead to the fact that the ECU fails. However, to recover released so the computer can overwriting firmware for K-Line .
Writing FLASH Memory ECU Siemens SIM2K-D160 is carried out only by K-Line.
Siemens SIM2K-140 is carried out by K-Line and recording ECU
Siemens SIM2K-141/341 is carried out on the CAN bus .
Siemens SIM2K-140 is carried out on the CAN bus.
If you try to write the firmware in the FLASH memory of the ECU, which is written by K-Line firmware on the CAN bus, it can lead to the fact that the ECU fails. However, to recover released so the computer can overwriting firmware for K-Line .
Writing FLASH Memory ECU Siemens SIM2K-D160 is carried out only by K-Line.
Warning: The following error is possible when writing: "Error accessing"
In such a case, turn off, then turn the ignition, and after waiting a pause of about 30 seconds. try to re-execute the write operation.
In some cases, turning off the ignition may not be enough, and need to completely disconnect the computer.
It should be noted that not all firmware ECU Siemens SIM2K-140/141 / D160
interchangeable with each other. ECU determines itself, it is suitable writing firmware or not.
This check takes place on the very last stage of the writing process.
If an error occurs during the transfer operation in the diagnostic mode,
it can mean that the recording is rejected ECU firmware. Car after such an operation will not start, but the computer itself is restored, if it re-write the firmware that is suitable for this type of computer.
This module implements automatic failover control unit. This means that the program ChipLoader anyway restore the computer after every unsuccessful EEPROM write operation, if the firmware is compatible to a given computer .
Computer software supports the following modes:
The correct size of the firmware FLASH memory for ECU Siemens SIM2K-140/141/341 / D160 - 2048 Kb (2097152 bytes).
As the format of firmware Siemens SIM2K-140/141/341 / D160 used BDM format .
To configure the computer to work with the data there is a separate tab in the program settings window:
In such a case, turn off, then turn the ignition, and after waiting a pause of about 30 seconds. try to re-execute the write operation.
In some cases, turning off the ignition may not be enough, and need to completely disconnect the computer.
It should be noted that not all firmware ECU Siemens SIM2K-140/141 / D160
interchangeable with each other. ECU determines itself, it is suitable writing firmware or not.
This check takes place on the very last stage of the writing process.
If an error occurs during the transfer operation in the diagnostic mode,
it can mean that the recording is rejected ECU firmware. Car after such an operation will not start, but the computer itself is restored, if it re-write the firmware that is suitable for this type of computer.
This module implements automatic failover control unit. This means that the program ChipLoader anyway restore the computer after every unsuccessful EEPROM write operation, if the firmware is compatible to a given computer .
Computer software supports the following modes:
- Record FLASH
- computer passport\Identification
The correct size of the firmware FLASH memory for ECU Siemens SIM2K-140/141/341 / D160 - 2048 Kb (2097152 bytes).
As the format of firmware Siemens SIM2K-140/141/341 / D160 used BDM format .
To configure the computer to work with the data there is a separate tab in the program settings window:
Before working with the computer in this family, you must first select the right type of computer in the " Computer Type the Siemens ". Wrong choice of the type of computer can crash during recording. However, the computer can be restored after such a failure, re-writing it in the firmware after selecting the right type of computer.
Repeatedly adjusting the ECU firmware is recommended to select the option "Record only Siemens ECU calibration ." This will speed up the firmware on the order entry process.
When you set the option " via the CAN bus via Work J2534 device " all work is carried out with the computer via the CAN bus. Otherwise - K-lines.
When you set the option " Forced to count COP calibration " is carried out recalculation of the checksum field calibrations when writing FLASH memory.
Repeatedly adjusting the ECU firmware is recommended to select the option "Record only Siemens ECU calibration ." This will speed up the firmware on the order entry process.
When you set the option " via the CAN bus via Work J2534 device " all work is carried out with the computer via the CAN bus. Otherwise - K-lines.
When you set the option " Forced to count COP calibration " is carried out recalculation of the checksum field calibrations when writing FLASH memory.
Caution During recording FLASH Memory ECU possible long pauses (25-30 sec.) Required for the performance of technical operations with a computer. This is a normal process, and not hang the computer or program.
Connecting to a computer terminal Siemens SIM2K-140/141/341 / D160 on the table
(large connector):
1,3,5 - ECU GND (just plug one of the contacts)
77 - CAN-High
78 - CAN-Low
76 - K-Line
2 - + 12V (ignition)
4 - + 12V (main relay power)
6 - + 12V (non-tripping power)
64 - main relay control output
Note that when working with the computer SIM2K-140/141/341 / D160 on a table, be sure to be connected via a relay output to control the main relay (64th Computer track). Otherwise, the EEPROM write operation can not successfully pass.