CHIPLOADER SETTING
After Installing the CHIPLOADER Software, from program menu, select SETTING to adjust as the following
The following Menu will appear
In the field Used COM port it is necessary to choose a COM port, to which a USB KLine adapter is connected. In the field ECU Baud rate it is necessary to choose baud rate with ECU via boot mode.
pay your attention to the fact that this field is not used for ECUs, that setup via right button mouse).
On the corresponding tab of the setup window you can choose a J2534 device, which you will use for work:
On the corresponding tab of the setup window you can choose a J2534 device, which you will use for work:
In order to setup work with ECU via OBD2 it is necessary to open a setup window for it with pressing the right mouse button on the ECU name:
Work with ECU Siemens via boot mode “on the table”.
There are 3 modules to work with ECU Siemens via boot mode:
1. Siemens 5WY SIMK41/43/EMS3132/Sirius
2. Siemens 5WY (5 sockets)/SIMK31/MS43
3. Siemens 5WPxxxx(Simos 7.1)
2. Siemens 5WY (5 sockets)/SIMK31/MS43
3. Siemens 5WPxxxx(Simos 7.1)
In order to switch into the boot mode while working with ECUs (included into before mentioned modules) you need to connect 104 pin of the processor C167 with the ground through a resistor of about 6.310KOhm
You have to do this before switching power on the ECU. While working with the ECU “on the table” via boot mode, it is necessary to connect power, ground, Kline to the ECU in accordance with the pinout of the ECU.
After power on of the ECU you need to choose the necessary module Siemens and press the button “Connect to ECU”. After that you can carry out operations like «Read Flash», «Write Flash».
All the works with the before mentioned ECUs are carried out via a USB KLine adapter. It is necessary to set up a USB KLine adapter in order it works properly. In order to set it up, you have to set up «Latency time», which you can change using «Device manager» of OS Windows, where you need to choose a virtual COM port, used for a USB KLine adapter. Default value for «Latency time» is equal to 16. It is necessary to change this value to 1 in order that the program works properly.
In the Russian version of Windows this setup window looks like that (where you need to find the blue field with number 16 and change it into 1):
All the before mentioned information for the ECU Siemens is also used for the ECU Bosch ME7.x, Kefico with the processor C167. To work with these ECUs you need to choose the module Bosch ME7.x/Simtec76boot mode or Bosch M7.9.x/Kefico – boot mode (depending on the ECU type).